OXFORD PLASMALAB 100 DRY / PLASMA ETCH
    설명
    There are 3 main problems with the system: 1) Neither AMU is in working condition 2) There is an internal leak in the system, which we believe is coming from CDA and/or related to the slit valve. 3) The backing pumps have failed repeated, likely related to vacuum leak The status of parts on the tool: 1) ICP AMU – Installed, not working 2) RIE AMU – Not installed, but we have the original unit. The original unit does not work. 3) ICP Power Supply – Not installed. Unsure if working. 4) Endpoint detection system – Not installed. Unsure if working. 5) Backing pump – None, two prior pumps have failed 6) All other parts of the tool are present and installed. Besides the vacuum leak, all other parts were working at last shutdown.
    환경 설정
    Gases: -Process Delivery Line -CH4 – Methane -H2 – Hydrogen -CHF3 – Trifluoromethane -O2 – Oxygen -CF4 – Tetraflouromethane -Ar – Argon -N2 – Nitrogen -HBr – Hydrogen Bromine
    OEM 모델 설명
    미제공
    문서

    문서 없음

    verified-listing-icon

    검증됨

    카테고리
    Dry / Plasma Etch

    마지막 검증일: 2일 전

    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    116201


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    알 수 없음


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    유사 등재물
    모두 보기
    OXFORD PLASMALAB 100 DRY / PLASMA ETCH

    OXFORD

    PLASMALAB 100 DRY / PLASMA ETCH

    Dry / Plasma Etch
    빈티지: 0조건: 중고
    마지막 검증일2일 전

    OXFORD

    PLASMALAB 100 DRY / PLASMA ETCH

    verified-listing-icon
    검증됨
    카테고리
    Dry / Plasma Etch
    마지막 검증일: 2일 전
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/d49d83e90deb44df9ba79b465a7b9db1_image25_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/934f8253403244ad925b865df9836811_image26_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/a1810aa0a9974ab697f1ad504f877248_image27_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/2098b137d6d54a029a5c24cc76832769_image28_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/21a135bad71e47928a1ef91438b36276_image29_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/9423178c6b6d4a70b41c6929090eb97f_image31_mw.jpg
    listing-photo-637ad81b7348447cab93601ac6549e04-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/76058/637ad81b7348447cab93601ac6549e04/bab590e7d1764a0d91204e433e3fac63_image30_mw.jpg
    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    116201


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    알 수 없음


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    설명
    There are 3 main problems with the system: 1) Neither AMU is in working condition 2) There is an internal leak in the system, which we believe is coming from CDA and/or related to the slit valve. 3) The backing pumps have failed repeated, likely related to vacuum leak The status of parts on the tool: 1) ICP AMU – Installed, not working 2) RIE AMU – Not installed, but we have the original unit. The original unit does not work. 3) ICP Power Supply – Not installed. Unsure if working. 4) Endpoint detection system – Not installed. Unsure if working. 5) Backing pump – None, two prior pumps have failed 6) All other parts of the tool are present and installed. Besides the vacuum leak, all other parts were working at last shutdown.
    환경 설정
    Gases: -Process Delivery Line -CH4 – Methane -H2 – Hydrogen -CHF3 – Trifluoromethane -O2 – Oxygen -CF4 – Tetraflouromethane -Ar – Argon -N2 – Nitrogen -HBr – Hydrogen Bromine
    OEM 모델 설명
    미제공
    문서

    문서 없음

    유사 등재물
    모두 보기
    OXFORD PLASMALAB 100 DRY / PLASMA ETCH

    OXFORD

    PLASMALAB 100 DRY / PLASMA ETCH

    Dry / Plasma Etch빈티지: 0조건: 중고마지막 검증일:2일 전
    OXFORD PLASMALAB 100 DRY / PLASMA ETCH

    OXFORD

    PLASMALAB 100 DRY / PLASMA ETCH

    Dry / Plasma Etch빈티지: 0조건: 중고마지막 검증일:2일 전
    OXFORD PLASMALAB 100 DRY / PLASMA ETCH

    OXFORD

    PLASMALAB 100 DRY / PLASMA ETCH

    Dry / Plasma Etch빈티지: 0조건: 중고마지막 검증일:2일 전