Chamber Specifications Temperature Range: -45 C to +190 C (-49 F to +375 F) Control & Stability: 0.5 C ( 1 F) at steady state condition after stabilization Weight & Dimensions: (Addition of certain options may increase dimensions) Interior: 38”W x 38”D x 38”H (97cm x 97cm x 97cm) Exterior: 50”W x 71”D x 91.5”H (127cm x 180cm x 232cm) Work Space: 32 Cubic Ft (905 L) Ship Weight: Approximately 1,730 lbs. (331 kg) Shelf Area: Distributed shelf load capacity is 100 lbs. (45 kg) and concentrated load is 50 lbs. (28 kg). Maximum number of shelves is 13 with maximum total weight of 250 lbs. (113kg). Floor Rating: Maximum floor load per chamber is 200 lbs. (91 kg), evenly distributed, including shelves with 20 lbs./ft2. Maximum total weight in the chamber is 450 lbs. (204 kg). Chamber Air Flow: 900 CFM환경 설정
ZP - Z-Plus Tundra Temperature 32 - 32 Cubic Ft (905 L) 6 - 6HP R-410A Tundra Refrigeration System SCT/WC - Scroll Tundra, Integral Water Cooled CondenserOEM 모델 설명
미제공문서
문서 없음
CINCINNATI SUB ZERO (CSZ)
ZP-32-6-SCT/WC
검증됨
카테고리
Environmental Chambers
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
54120
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
CINCINNATI SUB ZERO (CSZ)
ZP-32-6-SCT/WC
카테고리
Environmental Chambers
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
54120
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
Chamber Specifications Temperature Range: -45 C to +190 C (-49 F to +375 F) Control & Stability: 0.5 C ( 1 F) at steady state condition after stabilization Weight & Dimensions: (Addition of certain options may increase dimensions) Interior: 38”W x 38”D x 38”H (97cm x 97cm x 97cm) Exterior: 50”W x 71”D x 91.5”H (127cm x 180cm x 232cm) Work Space: 32 Cubic Ft (905 L) Ship Weight: Approximately 1,730 lbs. (331 kg) Shelf Area: Distributed shelf load capacity is 100 lbs. (45 kg) and concentrated load is 50 lbs. (28 kg). Maximum number of shelves is 13 with maximum total weight of 250 lbs. (113kg). Floor Rating: Maximum floor load per chamber is 200 lbs. (91 kg), evenly distributed, including shelves with 20 lbs./ft2. Maximum total weight in the chamber is 450 lbs. (204 kg). Chamber Air Flow: 900 CFM환경 설정
ZP - Z-Plus Tundra Temperature 32 - 32 Cubic Ft (905 L) 6 - 6HP R-410A Tundra Refrigeration System SCT/WC - Scroll Tundra, Integral Water Cooled CondenserOEM 모델 설명
미제공문서
문서 없음