    설명
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    환경 설정
    환경 설정 없음
    OEM 모델 설명
    미제공
    문서

    문서 없음

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon

    검증됨

    카테고리
    Environmental Chambers

    마지막 검증일: 60일 이상 전

    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    52017


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    1981


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    유사 등재물
    모두 보기
    THERMOTRON FM-16-CHM-5-5

    THERMOTRON

    FM-16-CHM-5-5

    Environmental Chambers
    빈티지: 1981조건: 중고
    마지막 검증일60일 이상 전

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon
    검증됨
    카테고리
    Environmental Chambers
    마지막 검증일: 60일 이상 전
    listing-photo-5ae5c270363e4d9c8a9220cf50dd1a9c-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    52017


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    1981


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    설명
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    환경 설정
    환경 설정 없음
    OEM 모델 설명
    미제공
    문서

    문서 없음

    유사 등재물
    모두 보기
    THERMOTRON FM-16-CHM-5-5

    THERMOTRON

    FM-16-CHM-5-5

    Environmental Chambers빈티지: 1981조건: 중고마지막 검증일:60일 이상 전