설명
Parametric Tester
환경 설정
환경 설정 없음
OEM 모델 설명
The standard system cabinet contains the 4072A/4073A tester system instruments and is 1.6 m (5.3 ft.) high. The standard cabinet has an emergency off (EMO) unit. The 4072A/4073A tester requires single phase power configuration with protective earth. Its line voltage is 200, 208, 220, or 240 Vac, and line frequency is 50 or 60 Hz. The line voltage and frequency are selected by specifying options. The system cabinet for the 4072A/4073A tester is equipped with a power distribution unit (PDU) for each line voltage. The rated current of the PDU is 20 A for 200/220/240 Vac, and 24 A for 208 Vac. The short circuit current rating is 5 kA for 200/220/240 Vac, and 10 kA for 208 Vac.
문서

문서 없음

카테고리
Final Test

마지막 검증일: 60일 이상 전

주요 품목 세부 정보

조건:

Used


작동 상태:

알 수 없음


제품 ID:

119595


웨이퍼 사이즈:

8"/200mm


빈티지:

알 수 없음


Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available

KEYSIGHT / AGILENT / HEWLETT-PACKARD (HP)

4072A

verified-listing-icon
검증됨
카테고리
Final Test
마지막 검증일: 60일 이상 전
listing-photo-5d381e854fd64586b67f84cfe2462664-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
주요 품목 세부 정보

조건:

Used


작동 상태:

알 수 없음


제품 ID:

119595


웨이퍼 사이즈:

8"/200mm


빈티지:

알 수 없음


Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
Parametric Tester
환경 설정
환경 설정 없음
OEM 모델 설명
The standard system cabinet contains the 4072A/4073A tester system instruments and is 1.6 m (5.3 ft.) high. The standard cabinet has an emergency off (EMO) unit. The 4072A/4073A tester requires single phase power configuration with protective earth. Its line voltage is 200, 208, 220, or 240 Vac, and line frequency is 50 or 60 Hz. The line voltage and frequency are selected by specifying options. The system cabinet for the 4072A/4073A tester is equipped with a power distribution unit (PDU) for each line voltage. The rated current of the PDU is 20 A for 200/220/240 Vac, and 24 A for 208 Vac. The short circuit current rating is 5 kA for 200/220/240 Vac, and 10 kA for 208 Vac.
문서

문서 없음