
설명
Fully automated, gravimetric, dual sample water vapor sorption analyzer.환경 설정
Specifications: Balance heads: 2 Balances, type: ultrasensitive electronic microbalances Balance load capacity(each): 5g Balance load capacity(combined): 10g Dynamic weighing range(each): -500mg to + 500mg, 0 to +1000mg Dynamic weighing range(combined): -1000mg to +1000mg, 0 to + 2000mg Weighing resolution: 0.1µg RH range: <2% - 98% (depending on temperature) RH resolution: 0.1% RH accuracy: ± 0.8% RH at 25°C Sample chamber temperature range: 10 - 80°C Sample Chamber Temperature: Accuracy/stability: ± 0.2°C Balance head temperature : ambient - 85°C (independently controlled) Gas flow rates: 0 - 200 cm3/min (mass flow controllers) Viewing port / sample chamber door: heated, triple-glazed Data acquisition rate: adjustable, up to 12 points per minute Sample pan material: silica Water reservoir capacity: 46 m Comes with software installed on a Windows computer Applications: Polymer hydrolytic stability and analysis Pharmaceuticals and excipients Composites and elastomers Additives and fillers characterizationOEM 모델 설명
미제공문서
문서 없음
카테고리
Inspection Equipment
마지막 검증일: 3일 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
154185
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
Quantachrome
Aquadyne DVS-2 DVS
카테고리
Inspection Equipment
마지막 검증일: 3일 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
154185
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
Fully automated, gravimetric, dual sample water vapor sorption analyzer.환경 설정
Specifications: Balance heads: 2 Balances, type: ultrasensitive electronic microbalances Balance load capacity(each): 5g Balance load capacity(combined): 10g Dynamic weighing range(each): -500mg to + 500mg, 0 to +1000mg Dynamic weighing range(combined): -1000mg to +1000mg, 0 to + 2000mg Weighing resolution: 0.1µg RH range: <2% - 98% (depending on temperature) RH resolution: 0.1% RH accuracy: ± 0.8% RH at 25°C Sample chamber temperature range: 10 - 80°C Sample Chamber Temperature: Accuracy/stability: ± 0.2°C Balance head temperature : ambient - 85°C (independently controlled) Gas flow rates: 0 - 200 cm3/min (mass flow controllers) Viewing port / sample chamber door: heated, triple-glazed Data acquisition rate: adjustable, up to 12 points per minute Sample pan material: silica Water reservoir capacity: 46 m Comes with software installed on a Windows computer Applications: Polymer hydrolytic stability and analysis Pharmaceuticals and excipients Composites and elastomers Additives and fillers characterizationOEM 모델 설명
미제공문서
문서 없음