SELA/Camtek MC-500 Die/Wafer Microcleaver System ***This unit was donated to a local university by Texas Instruments. It powers up and loads the software. It looks to be functional.*** Brief Description: Fully Automatic Cross Sectioning System for Die and Wafer Level Samples. Dedicated software enables automatic mapping and planning of a single target. Fully automatic and programmable process. Minimum operator involvement. Improved and enhanced SEM and FIB utilization. Input: Minimum 4.2 x 2.1, Accuracy: 0.5 micrometers, 1 sigma. Throughput: 15 minutes/sample. Software: Dedicated, based on Windows 95.환경 설정
The Unit's Serial Number Tag Reads: Model Number: MC 500 Serial Number: 05-521 Power Requirements: 115 V, 50/60 Hz, 16 A Air Pressure: 7 atm (110 psi) min. Information from the Unit: Software Version: MC500 v2.9 Optics: Eye Pieces: Olympus WH10X-H/22 and WH10X/22 Ojbectives: LMPlan FI 100X/0.80, ∞/0 LMPlan FI 50X/0.50, ∞/0 UMPlan FI 10X/0.30, ∞/0 MPlan APO 2.5X/0.08, ∞/-OEM 모델 설명
미제공문서
문서 없음
카테고리
Inspection Equipment
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
Deinstalled / Uncrated
제품 ID:
126958
웨이퍼 사이즈:
알 수 없음
HDD / Software:
Yes
빈티지:
알 수 없음
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
CAMTEK / SELA
MC500
카테고리
Inspection Equipment
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
Deinstalled / Uncrated
제품 ID:
126958
웨이퍼 사이즈:
알 수 없음
HDD / Software:
Yes
빈티지:
알 수 없음
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
SELA/Camtek MC-500 Die/Wafer Microcleaver System ***This unit was donated to a local university by Texas Instruments. It powers up and loads the software. It looks to be functional.*** Brief Description: Fully Automatic Cross Sectioning System for Die and Wafer Level Samples. Dedicated software enables automatic mapping and planning of a single target. Fully automatic and programmable process. Minimum operator involvement. Improved and enhanced SEM and FIB utilization. Input: Minimum 4.2 x 2.1, Accuracy: 0.5 micrometers, 1 sigma. Throughput: 15 minutes/sample. Software: Dedicated, based on Windows 95.환경 설정
The Unit's Serial Number Tag Reads: Model Number: MC 500 Serial Number: 05-521 Power Requirements: 115 V, 50/60 Hz, 16 A Air Pressure: 7 atm (110 psi) min. Information from the Unit: Software Version: MC500 v2.9 Optics: Eye Pieces: Olympus WH10X-H/22 and WH10X/22 Ojbectives: LMPlan FI 100X/0.80, ∞/0 LMPlan FI 50X/0.50, ∞/0 UMPlan FI 10X/0.30, ∞/0 MPlan APO 2.5X/0.08, ∞/-OEM 모델 설명
미제공문서
문서 없음