THERMOFISHER SCIENTIFIC / FEI / PHILIPS QUANTA 400 FEG
    설명
    ESEM
    환경 설정
    High vacuum Low vacuum ESEM modes FEG source: Sirion FEG column Detectors: ETD, LFD, SSBSED and GAD Hot stage and cold stage BEAM: – Emitter: FEG – Acceleration voltage range: 200 V to 30 kV – Probe current: 100 nA, adjustable – Chamber end pressure (high vacuum): < 6 x 10-4 Pa – Vacuum system: 1 x 240 l/s TMP, 2 x PVP RESOLUTION: - High vacuum (30 kV): 2 nm - Low vacuum (3 kV): 3.5 nm - Astigmatism (WD variation): < 25 µm (30 kV) | < 25 µm (5 kV) | < 50 µm (1 kV) DETECTORS: - SED: High-vacuum secondary electrons - LFD: Low-vacuum secondary electrons - SSBSED: Solid-state backscattered electrons - GAD: Gaseous analytical (factory option) STAGE: - Type: 5-axis motorized pseudo-eucentric - Travel (X, Y, Z): 100 × 100 × 60 mm (75 mm Z-clearance) - Tilt: -5° to +70° (WD dependent) - Rotation: 360° continuous - Analytical WD: 10 mm
    OEM 모델 설명
    미제공
    문서

    문서 없음

    verified-listing-icon

    검증됨

    카테고리
    SEM / FIB

    마지막 검증일: 16일 전

    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    157758


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    2005


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    유사 등재물
    모두 보기
    THERMOFISHER SCIENTIFIC / FEI / PHILIPS QUANTA 400 FEG

    THERMOFISHER SCIENTIFIC / FEI / PHILIPS

    QUANTA 400 FEG

    SEM / FIB
    빈티지: 2005조건: 중고
    마지막 검증일16일 전

    THERMOFISHER SCIENTIFIC / FEI / PHILIPS

    QUANTA 400 FEG

    verified-listing-icon
    검증됨
    카테고리
    SEM / FIB
    마지막 검증일: 16일 전
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398394/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398395/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398403/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398396/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398397/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398398/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398404/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398399/image/md.jpeg
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398405/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398400/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398406/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398402/image/md.png
    listing-photo-41432b7b8869435cae74a685a0a4574d-https://api-v2.moov.co/listingPhotos/398401/image/md.png
    주요 품목 세부 정보

    조건:

    Used


    작동 상태:

    알 수 없음


    제품 ID:

    157758


    웨이퍼 사이즈:

    알 수 없음


    빈티지:

    2005


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    설명
    ESEM
    환경 설정
    High vacuum Low vacuum ESEM modes FEG source: Sirion FEG column Detectors: ETD, LFD, SSBSED and GAD Hot stage and cold stage BEAM: – Emitter: FEG – Acceleration voltage range: 200 V to 30 kV – Probe current: 100 nA, adjustable – Chamber end pressure (high vacuum): < 6 x 10-4 Pa – Vacuum system: 1 x 240 l/s TMP, 2 x PVP RESOLUTION: - High vacuum (30 kV): 2 nm - Low vacuum (3 kV): 3.5 nm - Astigmatism (WD variation): < 25 µm (30 kV) | < 25 µm (5 kV) | < 50 µm (1 kV) DETECTORS: - SED: High-vacuum secondary electrons - LFD: Low-vacuum secondary electrons - SSBSED: Solid-state backscattered electrons - GAD: Gaseous analytical (factory option) STAGE: - Type: 5-axis motorized pseudo-eucentric - Travel (X, Y, Z): 100 × 100 × 60 mm (75 mm Z-clearance) - Tilt: -5° to +70° (WD dependent) - Rotation: 360° continuous - Analytical WD: 10 mm
    OEM 모델 설명
    미제공
    문서

    문서 없음

    유사 등재물
    모두 보기
    THERMOFISHER SCIENTIFIC / FEI / PHILIPS QUANTA 400 FEG

    THERMOFISHER SCIENTIFIC / FEI / PHILIPS

    QUANTA 400 FEG

    SEM / FIB빈티지: 2005조건: 중고마지막 검증일:16일 전