설명
NEW Disco DTU162 Water Temperature Control Unit Support for Dicing Quality: The DTU162 keeps both spindle cooling water and cutting water at a constant temperature and suitable pressure. It thereby helps manage expansion, contraction, and other undesirable pheomena caused by water temperature fluctuation. Reduced Environmental Impact: By circulating used cutting water and precipitation filtration of water-borne debris, the DTU162 significantly reduces water consumption and environmental impact. Further, the refrigerant used in the DTU162 is a completely non-ozone-depleting hydrofluorocarbon (R-407C). Small Footprint: The efficient design of the DTU162's interior makes a very small unit footprint possible. Easy Maintenance: Use of long 20" filters allows for less frequent replacements. Interior layout designed for maximizing the simplicity of regular maintenance.환경 설정
The Unit's Serial Number Tag Reads: Model Number: DTU162 Disco Number: LWGH-010004-6 Date of Manufacture: 2010.10.26 Power Requirements: 200/200~220 VAC ±10%, 3-Phase, 50/60 Hz, 20.4 F.L. Amps Water Pressure & Flow Rate: 0.30 MPa / 10 L/min R.C.W. Pressure: 0.2 ~ 0.5 MPa Mass: 240 kg Specifications: Range Required to Guarantee Accuracy: Cooling Water Line: 20 ~ 25°C Cutting Water Line: 20 ~ 27°C and within 2°C of the spindle coolant setting Temperature Accuracy: 1°C Cooling Efficiency: 0.6 kW Heating Efficiency: Cooling Water Line: 0.6 kW Cutting Water Line: 2 kW Flow Rate: Cooling Water Line: 6 L/min Cutting Water Line: 10 L/min Circulating Method: Recirculation type Dimensions: 430 mm W x 900 mm D x 1,500 mm H Machine Weight: Approx. 240 kg when fullOEM 모델 설명
Higher Dicing quality with lower environmental impact Support for dicing quality The DTU162 keeps both spindle cooling water and cutting water at a constant temperature and suitable pressure. It thereby helps manage expansion, contraction, and other undesirable phenomena caused by water temperature fluctuation.문서
문서 없음
유사 등재물
모두 보기DISCO
DTU162
카테고리
Support Equipment
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
New
작동 상태:
Deinstalled / Uncrated
제품 ID:
126114
웨이퍼 사이즈:
알 수 없음
빈티지:
2010
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
NEW Disco DTU162 Water Temperature Control Unit Support for Dicing Quality: The DTU162 keeps both spindle cooling water and cutting water at a constant temperature and suitable pressure. It thereby helps manage expansion, contraction, and other undesirable pheomena caused by water temperature fluctuation. Reduced Environmental Impact: By circulating used cutting water and precipitation filtration of water-borne debris, the DTU162 significantly reduces water consumption and environmental impact. Further, the refrigerant used in the DTU162 is a completely non-ozone-depleting hydrofluorocarbon (R-407C). Small Footprint: The efficient design of the DTU162's interior makes a very small unit footprint possible. Easy Maintenance: Use of long 20" filters allows for less frequent replacements. Interior layout designed for maximizing the simplicity of regular maintenance.환경 설정
The Unit's Serial Number Tag Reads: Model Number: DTU162 Disco Number: LWGH-010004-6 Date of Manufacture: 2010.10.26 Power Requirements: 200/200~220 VAC ±10%, 3-Phase, 50/60 Hz, 20.4 F.L. Amps Water Pressure & Flow Rate: 0.30 MPa / 10 L/min R.C.W. Pressure: 0.2 ~ 0.5 MPa Mass: 240 kg Specifications: Range Required to Guarantee Accuracy: Cooling Water Line: 20 ~ 25°C Cutting Water Line: 20 ~ 27°C and within 2°C of the spindle coolant setting Temperature Accuracy: 1°C Cooling Efficiency: 0.6 kW Heating Efficiency: Cooling Water Line: 0.6 kW Cutting Water Line: 2 kW Flow Rate: Cooling Water Line: 6 L/min Cutting Water Line: 10 L/min Circulating Method: Recirculation type Dimensions: 430 mm W x 900 mm D x 1,500 mm H Machine Weight: Approx. 240 kg when fullOEM 모델 설명
Higher Dicing quality with lower environmental impact Support for dicing quality The DTU162 keeps both spindle cooling water and cutting water at a constant temperature and suitable pressure. It thereby helps manage expansion, contraction, and other undesirable phenomena caused by water temperature fluctuation.문서
문서 없음