설명
설명 없음환경 설정
Specifications: Read modes: Absorbance, Fluorescence (top/bottom read), Luminescence (top read) Wavelength ranges: Abs: 230 - 1000 nm; FL Ex: 250 - 830 nm; FL Em: 270 - 850 nm; Lumi: 300 - 850 nm Wavelength selection: Monochromator tunable in 1-nm increments Absorbance photometric accuracy/linearity: < ±0.010 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV Absorbance photometric precision/repeatability: < ±0.003 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV Sensitivity to read optimized: FL: 1 pM fluoresein 96 well, 1 pM fluorescein 384 well; Lumi: 2 pM ATP 96 well, 4 pM Light source(s): High power xenon flash lamp Detector(s): Silicon photodiode, Ultra-cooled photomultiplier tube Read types (endpoint, kinetic, etc): Endpoint, Kinetic, Spectrum scan, Well scan Read times: Abs: 28 seconds; FL: 21 seconds; Lumi: 21 seconds Plate shaking: Linear, Orbital, Double orbital Injectors: Yes Western Blot: No Stand-alone touchscreen operations: Yes Robotics/automation: Yes Plate type(s): 6-384 well plates Temperature control: Yes, Ambient + 5°C to 66°C Validation tools: Absorbance validation plate, Fluorescence validation plate, Luminescence validation plate, SoftMax Pro GxP Software Dimensions: 21" W x 23.5" D x 15.8" H (53.2 x 59.8 x 40.1 cm)OEM 모델 설명
The SpectraMax® iD3 Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence.문서
문서 없음
MOLECULAR DEVICES
SpectraMax iD3
검증됨
카테고리
Support Equipment
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
78766
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
MOLECULAR DEVICES
SpectraMax iD3
카테고리
Support Equipment
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
78766
웨이퍼 사이즈:
알 수 없음
빈티지:
알 수 없음
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
설명 없음환경 설정
Specifications: Read modes: Absorbance, Fluorescence (top/bottom read), Luminescence (top read) Wavelength ranges: Abs: 230 - 1000 nm; FL Ex: 250 - 830 nm; FL Em: 270 - 850 nm; Lumi: 300 - 850 nm Wavelength selection: Monochromator tunable in 1-nm increments Absorbance photometric accuracy/linearity: < ±0.010 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV Absorbance photometric precision/repeatability: < ±0.003 OD ±1.0%, 0 - 3 OD VIS 0 - 3 OD UV Sensitivity to read optimized: FL: 1 pM fluoresein 96 well, 1 pM fluorescein 384 well; Lumi: 2 pM ATP 96 well, 4 pM Light source(s): High power xenon flash lamp Detector(s): Silicon photodiode, Ultra-cooled photomultiplier tube Read types (endpoint, kinetic, etc): Endpoint, Kinetic, Spectrum scan, Well scan Read times: Abs: 28 seconds; FL: 21 seconds; Lumi: 21 seconds Plate shaking: Linear, Orbital, Double orbital Injectors: Yes Western Blot: No Stand-alone touchscreen operations: Yes Robotics/automation: Yes Plate type(s): 6-384 well plates Temperature control: Yes, Ambient + 5°C to 66°C Validation tools: Absorbance validation plate, Fluorescence validation plate, Luminescence validation plate, SoftMax Pro GxP Software Dimensions: 21" W x 23.5" D x 15.8" H (53.2 x 59.8 x 40.1 cm)OEM 모델 설명
The SpectraMax® iD3 Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence.문서
문서 없음