설명
Soft laser marking system Laser Status : Laser Recommended Value Actual Value Sigma < 0.5 0.24 WB < 100 60 Current < 120 120 Max Power 2.4W 1.69W환경 설정
Known issues: Laser output measured 1.69 W at current 120 and pulsewidth 195; report specifies output should exceed 2.4 W and recommends diode / flowcell replacement (both used over 3.5 years) CE calibration cannot be written normally; LPC replacement recommended X / Y galvos do not move during manual jobs, causing marking at the same point on the wafer; ME2 marker driver control board replacement recommended Aligner repeatability could not be tested due to abnormal marker operation Handling: Crossing Automation Model 21 robot, P/N 12000-057, software 1.5D Edge-grip handling Quartet Mechanics EGPB edge-grip aligner with buffer, replacing Asyst aligner (Qty 2) Asyst load ports without OHT Software: WLM version 3.4.1 Application / Control version 3.4.15.0 Electrical: 220 VAC, 22 A, 50-60 HzOEM 모델 설명