NIKON I-line lithography machine Nikon I-line lithography machine uses a light source with a wavelength of 365nm and is a key device for fine pattern transfer in semiconductor manufacturing. The main models include the NSR series (step-and-projection type) and the 3 series (scanning type). They support a variety of wafer sizes and are widely used in the production of 2-inch, 4-inch, 6-inch, 8-inch and 12-inch wafers. This allows them to serve semiconductor production lines of different sizes and meet diverse production needs.환경 설정
0.28 0.62 4:1 26*33 FIA:45OEM 모델 설명
NSR-SF130, a scan-field i-line stepper with high throughput and extremely low cost of ownership. The system makes use of leading-edge lens technology to achieve the same wide exposure field (26×33 mm) as DUV scanners, making it ideal for mix and match applications. The NSR-SF130, Nikon’s fifth new semiconductor systems announced in 2003, achieves a resolution of 280 nm or better and boasts a throughput of 120 wafers/hour for 300 mm wafers. The system combines superior performance with the lowest cost of ownership to help reduce semiconductor manufacturing costs.문서
문서 없음
유사 등재물
모두 보기NIKON
NSR-SF130
카테고리
Steppers & Scanners
마지막 검증일: 60일 이상 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
131670
웨이퍼 사이즈:
2"/50mm, 4"/100mm, 6"/150mm, 8"/200mm, 12"/300mm
빈티지:
알 수 없음
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
NIKON I-line lithography machine Nikon I-line lithography machine uses a light source with a wavelength of 365nm and is a key device for fine pattern transfer in semiconductor manufacturing. The main models include the NSR series (step-and-projection type) and the 3 series (scanning type). They support a variety of wafer sizes and are widely used in the production of 2-inch, 4-inch, 6-inch, 8-inch and 12-inch wafers. This allows them to serve semiconductor production lines of different sizes and meet diverse production needs.환경 설정
0.28 0.62 4:1 26*33 FIA:45OEM 모델 설명
NSR-SF130, a scan-field i-line stepper with high throughput and extremely low cost of ownership. The system makes use of leading-edge lens technology to achieve the same wide exposure field (26×33 mm) as DUV scanners, making it ideal for mix and match applications. The NSR-SF130, Nikon’s fifth new semiconductor systems announced in 2003, achieves a resolution of 280 nm or better and boasts a throughput of 120 wafers/hour for 300 mm wafers. The system combines superior performance with the lowest cost of ownership to help reduce semiconductor manufacturing costs.문서
문서 없음