메인 콘텐츠로 건너뛰기
Moov logo

Moov Icon
LAM RESEARCH / NOVELLUS / GASONICS L3510
    설명
    The Gasonics L3510 plasma system is designed for ashing and cleaning semiconductor wafers. Gasonics L3510 does this by creating monatomic oxygen, the active specie, which chemically reacts with the photoresist on the surface of the wafer. The Gasonics L3510 system is composed of two main components: (1)The process sub-system The process sub-system includes the controller, the microwave generator, the gas flow control, the cassette platform, and the robot assembly. (2)he vacuum pump The vacuum pump is normally located in an adjacent equipment room separate from the main system. The pump should be kept running continuously. Gasonics L3510 Sequence of Steps in Plasma Ashing The following is a typical process sequence in the Run (automatic) mode: · The robot arm takes a wafer from the cassette and places it on the quartz pins in the plasma chamber. · The door closes to seal the chamber, the vacuum valve opens, and the chamber is pumped down to a preset pressure. · The quartz pins can lower the wafer onto the platen for heating, or raise it above the platen. In addition, the wafer can be heated by a variable-intensity halogen lamp located above the process chamber. · Process gases are introduced into the evacuated chamber while operating pressure is achieved and maintained by a closed-loop pressure control system. · The wafer can be heated by the platen during processing. If additional wafer heating is required, the heat lamp can be turned on for a programmable time. · Microwave power turns on and ignites a plasma in the plasma reactor chamber. This ignition is aided by a UV lamp in the plasma generation cavity. · The plasma generates atomic oxygen molecules, which flow from the plasma reactor chamber to the process chamber, then across the surface of the wafer, where they react with the photoresist molecules. Processing is ended by turning off the microwave power and the gas flows. This can be triggered either by an end of process (EOP) sensor or when a pre-programmed amount of time has passed. · If low-particulate processing is desired, the system purges slowly to 10 Torr, then purges quickly to atmospheric pressure before the door opens. · When processing is complete, the quartz pins raise the ashed wafer, allowing the robot arm to retrieve it and return it to the cassette. · If a cooling time has been requested, the wafer is placed on the cooling station. · While the wafer is cooling, the robot arm takes the next wafer and moves it to the process chamber, repeating the cycle. When the first wafer has cooled, it is returned to its original cassette slot.
    환경 설정
    Process Gasses: O2 and N2
    OEM 모델 설명
    PEP3510A is a dry chemistry downstream processing system for photoresist removal, manufactured by GaSonics. It incorporates the company’s proprietary microwave downstream processing technology and is designed for advanced IC manufacturers. The system can handle feature sizes of 0.25 microns and below, with throughput rates ranging from approximately 45 to 55 wafers per hour.
    문서

    문서 없음

    verified-listing-icon

    검증됨

    카테고리
    Ashers / Plasma Cleaner

    마지막 검증일: 21일 전

    주요 품목 세부 정보

    조건:

    Refurbished


    작동 상태:

    알 수 없음


    제품 ID:

    138436


    웨이퍼 사이즈:

    4"/100mm, 5"/125mm, 6"/150mm, 8"/200mm


    빈티지:

    알 수 없음


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    유사 등재물
    모두 보기
    LAM RESEARCH / NOVELLUS / GASONICS L3510

    LAM RESEARCH / NOVELLUS / GASONICS

    L3510

    Ashers / Plasma Cleaner
    빈티지: 0조건: 중고
    마지막 검증일60일 이상 전

    LAM RESEARCH / NOVELLUS / GASONICS

    L3510

    verified-listing-icon
    검증됨
    카테고리
    Ashers / Plasma Cleaner
    마지막 검증일: 21일 전
    listing-photo-788c23d025534cb69aa9919a3993a0f8-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/2186/788c23d025534cb69aa9919a3993a0f8/66b0a22263a14efeaa64ea63c82073f9_gasonicsl3510plasmaasherdescumequipment_mw.jpg
    주요 품목 세부 정보

    조건:

    Refurbished


    작동 상태:

    알 수 없음


    제품 ID:

    138436


    웨이퍼 사이즈:

    4"/100mm, 5"/125mm, 6"/150mm, 8"/200mm


    빈티지:

    알 수 없음


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    설명
    The Gasonics L3510 plasma system is designed for ashing and cleaning semiconductor wafers. Gasonics L3510 does this by creating monatomic oxygen, the active specie, which chemically reacts with the photoresist on the surface of the wafer. The Gasonics L3510 system is composed of two main components: (1)The process sub-system The process sub-system includes the controller, the microwave generator, the gas flow control, the cassette platform, and the robot assembly. (2)he vacuum pump The vacuum pump is normally located in an adjacent equipment room separate from the main system. The pump should be kept running continuously. Gasonics L3510 Sequence of Steps in Plasma Ashing The following is a typical process sequence in the Run (automatic) mode: · The robot arm takes a wafer from the cassette and places it on the quartz pins in the plasma chamber. · The door closes to seal the chamber, the vacuum valve opens, and the chamber is pumped down to a preset pressure. · The quartz pins can lower the wafer onto the platen for heating, or raise it above the platen. In addition, the wafer can be heated by a variable-intensity halogen lamp located above the process chamber. · Process gases are introduced into the evacuated chamber while operating pressure is achieved and maintained by a closed-loop pressure control system. · The wafer can be heated by the platen during processing. If additional wafer heating is required, the heat lamp can be turned on for a programmable time. · Microwave power turns on and ignites a plasma in the plasma reactor chamber. This ignition is aided by a UV lamp in the plasma generation cavity. · The plasma generates atomic oxygen molecules, which flow from the plasma reactor chamber to the process chamber, then across the surface of the wafer, where they react with the photoresist molecules. Processing is ended by turning off the microwave power and the gas flows. This can be triggered either by an end of process (EOP) sensor or when a pre-programmed amount of time has passed. · If low-particulate processing is desired, the system purges slowly to 10 Torr, then purges quickly to atmospheric pressure before the door opens. · When processing is complete, the quartz pins raise the ashed wafer, allowing the robot arm to retrieve it and return it to the cassette. · If a cooling time has been requested, the wafer is placed on the cooling station. · While the wafer is cooling, the robot arm takes the next wafer and moves it to the process chamber, repeating the cycle. When the first wafer has cooled, it is returned to its original cassette slot.
    환경 설정
    Process Gasses: O2 and N2
    OEM 모델 설명
    PEP3510A is a dry chemistry downstream processing system for photoresist removal, manufactured by GaSonics. It incorporates the company’s proprietary microwave downstream processing technology and is designed for advanced IC manufacturers. The system can handle feature sizes of 0.25 microns and below, with throughput rates ranging from approximately 45 to 55 wafers per hour.
    문서

    문서 없음

    유사 등재물
    모두 보기
    LAM RESEARCH / NOVELLUS / GASONICS L3510

    LAM RESEARCH / NOVELLUS / GASONICS

    L3510

    Ashers / Plasma Cleaner빈티지: 0조건: 중고마지막 검증일:60일 이상 전
    LAM RESEARCH / NOVELLUS / GASONICS L3510

    LAM RESEARCH / NOVELLUS / GASONICS

    L3510

    Ashers / Plasma Cleaner빈티지: 0조건: 중고마지막 검증일:60일 이상 전
    LAM RESEARCH / NOVELLUS / GASONICS L3510

    LAM RESEARCH / NOVELLUS / GASONICS

    L3510

    Ashers / Plasma Cleaner빈티지: 0조건: 중고마지막 검증일:60일 이상 전