i-Line Stepper Performance Specification: 1. Resolution: 0.35μm or less High resolution, positive resist film of 1.0μm thickness 2. Focus Calibration Repeatability: Within 100nm (3σ) 20 measurements 3. Lens Distortion (including magnification error): Within ± 40nm 37 points / chip 4. Magnification Control: Within ± 15nm 3 measurements of Initial, Heat (180min.) and Cool (240min.) 5. Maximum Exposure Area: Within 31.11mm dia. 22.0mm x 22.0mm to 17.96mm x 25.2mm (hor.) X (vert.) 6. Reticle Blind Setting Accuracy: + 0.4 to + 0.8mm (on reticle) 7. Exposure Power: 800 mW/cm2 or more Measured after a new lamp is installed 8. Integrated Exposure Stability (including integrated exposure matching): Within ± 1.0% (50 mJ/cm2 or more) Within ± 0.5% (at 100mJ/cm2) 9. Illumination Uniformity Within ± 1.0% Inside exposure area 5 measurementsOEM 모델 설명
"This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.문서
문서 없음
카테고리
Steppers & Scanners
마지막 검증일: 4일 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
148409
웨이퍼 사이즈:
6"/150mm
빈티지:
2006
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
유사 등재물
모두 보기NIKON
NSR-2205i12D
카테고리
Steppers & Scanners
마지막 검증일: 4일 전
주요 품목 세부 정보
조건:
Used
작동 상태:
알 수 없음
제품 ID:
148409
웨이퍼 사이즈:
6"/150mm
빈티지:
2006
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
설명
European CE Safety mark certification환경 설정
i-Line Stepper Performance Specification: 1. Resolution: 0.35μm or less High resolution, positive resist film of 1.0μm thickness 2. Focus Calibration Repeatability: Within 100nm (3σ) 20 measurements 3. Lens Distortion (including magnification error): Within ± 40nm 37 points / chip 4. Magnification Control: Within ± 15nm 3 measurements of Initial, Heat (180min.) and Cool (240min.) 5. Maximum Exposure Area: Within 31.11mm dia. 22.0mm x 22.0mm to 17.96mm x 25.2mm (hor.) X (vert.) 6. Reticle Blind Setting Accuracy: + 0.4 to + 0.8mm (on reticle) 7. Exposure Power: 800 mW/cm2 or more Measured after a new lamp is installed 8. Integrated Exposure Stability (including integrated exposure matching): Within ± 1.0% (50 mJ/cm2 or more) Within ± 0.5% (at 100mJ/cm2) 9. Illumination Uniformity Within ± 1.0% Inside exposure area 5 measurementsOEM 모델 설명
"This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.문서
문서 없음